Skip to content
FixCodes

Air Conditioner error codes

Air conditioner codes cover window, portable and mini-split units. Most point to a temperature sensor, a full water tank or blocked drain, a fan fault, or lost communication between the indoor and outdoor units.

How an air conditioner reports a fault

Room air conditioners and mini-splits use temperature sensors on the indoor coil, in the room air and, on split systems, on the outdoor coil and compressor. The control uses them to protect the system: it stops cooling if the indoor coil gets cold enough to ice up, and it stops heating or cooling if parts get too hot.

Split systems also have a communication wire between the indoor and outdoor units. If the boards stop talking, for example after a power surge or because of a loose wire, the unit shows a communication code. Portable units and some window units also have a water tank or pan, and they stop when it is full.

What to check first for any AC code

Clean or replace the air filter. A dirty filter is the most common reason an indoor coil freezes, and many coil temperature and protection codes clear once air can flow again.

On a portable unit, empty the water tank or check the drain hose. On a window unit, check that water can drain out of the back. On a mini-split, look at the condensate line where it leaves the wall and make sure it is not blocked or kinked.

Then turn the unit off at the breaker or unplug it for a few minutes. This resets the boards, and it often clears a communication code caused by a power glitch.

When it is time for a technician

Compressor, outdoor board, refrigerant and communication codes that keep returning need an HVAC technician. Any repair that involves refrigerant needs EPA certification, and the outdoor unit of a mini-split carries high voltage even after it has been switched off.

LG

CodeWhat it means
CH05Indoor and outdoor units not communicating (mini-split)
CH38Low refrigerant protection (mini-split)
CH61Unit overheating (mini-split)
CH10Fan motor fault (mini-split and window)
CH01Indoor temperature sensor fault (mini-split)
CH21Outdoor compressor or inverter fault (mini-split)
FLalso P2Water tank full (portable)
E1Indoor pipe sensor fault (window and portable)
E3No refrigerant detected (window and portable)

Frigidaire

CodeWhat it means
P1Bottom tray full (portable)
ASRoom temperature sensor failed
ESDefrost or humidity sensor failed
HSAir discharge sensor failed
F1Freeze protection engaged
F2Freeze protection (let the unit defrost)
ECCommunication error
LCIndoor and outdoor units not communicating (mini-split)

Haier

CodeWhat it means
E1Temperature sensor fault (split and portable)
E2Temperature sensor fault (split and portable)
E5Indoor coil anti-freeze protection (split)
E7Indoor/outdoor communication fault (split)
E9Overload in heating mode (split)
E14Indoor fan motor fault (split)
F1IPM inverter module protection (split)
F13Low refrigerant (split)
F19Supply voltage too high or low (split)
FLWater tank full (portable)

GE

CodeWhat it means
FLWater tank or pan full (portable and ClearView)
P1Drain pump problem (ClearView window)
E1Temperature sensor fault (portable)
E2Temperature sensor fault (portable)
E4Anti-freeze protection (portable)
ASRoom temperature sensor error (wall unit)
HSElectric heat sensor error (wall unit)
ESEvaporator sensor error (wall unit)

Fujitsu

CodeWhat it means
11also E11Indoor and outdoor units not communicating
12also E12Wired remote not communicating with indoor unit
41also E41Indoor room temperature sensor fault
42also E42Indoor coil (pipe) temperature sensor fault
51also E51Indoor fan motor fault
53also E53Drain pump fault (cassette and ducted units)
62also E62Outdoor unit main board error
63also E63Inverter error
97also E97Outdoor fan motor fault
99also E99Reversing (4-way) valve error
A1also EA1Discharge temperature too high

MRCOOL

CodeWhat it means
E1also EL 01Indoor and outdoor units not communicating
ECalso EL 0CRefrigerant leak or low refrigerant detected
EH 0Aalso EH 00, E0Indoor unit EEPROM (control board memory) error
E5also EH 61Indoor coil temperature sensor fault
P1also PC 01Over or under voltage protection
P4also PC 04Inverter compressor drive error
P6also PC 03Low pressure protection
F1also EC 53Outdoor ambient temperature sensor fault
F5also EC 07Outdoor fan speed out of control
E3also EH 03Indoor fan speed out of control
P0also PC 00Inverter module (IPM) protection

Danby

CodeWhat it means
P1also FtWater tray full (portable)
E1Room temperature sensor error (portable)
E2Evaporator sensor error (portable)
E3Condenser sensor error (portable)
E4Display board communication error (portable and window)
E7Power signal detection error (portable)
ASRoom temperature sensor error (window)
ESEvaporator sensor error (window)
LORoom too cold or sensor error (window)
HIRoom too hot or sensor error (window)
PFSensor failure (portable)