LG air conditioner error codes

LG air conditioners use two code styles. Ductless mini-splits show CH followed by two digits, such as CH05 or CH38, on the indoor unit display. Window and portable units use short codes such as E1, E3 and FL. On some portables the full tank code shows as P2 instead of FL.

The codes in this list cover communication between units (CH05), refrigerant (CH38, E3), overheating and airflow (CH61, CH10), temperature sensors (CH01, E1) and the outdoor compressor (CH21). FL is just a full water tank, and you can clear it yourself. CH05 is often a tripped breaker for the outdoor unit. CH61 and CH10 often come down to dirt or debris. Refrigerant, compressor and sensor codes need a technician.

CodeWhat it means
CH05Indoor and outdoor units not communicating (mini-split)
CH38Low refrigerant protection (mini-split)
CH61Unit overheating (mini-split)
CH10Fan motor fault (mini-split and window)
CH01Indoor temperature sensor fault (mini-split)
CH21Outdoor compressor or inverter fault (mini-split)
FLalso P2Water tank full (portable)
E1Indoor pipe sensor fault (window and portable)
E3No refrigerant detected (window and portable)

Codes you can usually fix yourself

FL (P2): drain the water tank or base pan. LG says this is not a fault. It happens when humid air makes water faster than the unit can get rid of it.

CH05: check the breaker and outdoor disconnect for the outdoor unit. The indoor unit can have power while the outdoor unit does not.

CH61 and CH10: clean the indoor filters, then clear leaves, snow or clutter from around the outdoor unit. Do not open any panels.

Codes that need a licensed technician

CH38 and E3 both point to lost refrigerant, usually from a leak. The leak has to be found and fixed before the system is recharged, so never add refrigerant yourself. CH21 involves the compressor and its drive circuit, and the outdoor unit holds high voltage even with the power off. If CH01 or E1 returns after a reset, the sensor or the board needs replacing.

Give the compressor time after a reset

After you restore power, the compressor normally waits about 3 minutes before it starts. Wait at least that long before you decide the reset did not work.

How to reset your LG air conditioner

  1. Turn the air conditioner off with the remote or the control panel.
  2. Cut the power for 5 minutes. Unplug window and portable units. For a mini-split, turn off the breaker and the outdoor disconnect switch if there is one.
  3. Restore power and turn the unit back on. The compressor normally waits about 3 minutes before starting, so give it time before judging.
  4. If the same code comes back straight away, the fault is still there. Work through the fix steps above, or call a technician.

Models these codes cover

  • Ductless mini-splits (wall-mounted and Art Cool)
  • Multi-zone mini-split systems
  • Window air conditioners
  • Portable air conditioners

What does the code on your appliance mean?

Type the code exactly as it shows on the display. We'll tell you what it means and how to fix it.

Air Conditioner codes from other brands