LG air conditioner E3 error code: no refrigerant detected (window and portable)
- Urgency
- High
- Who can fix it
- Technician job
- Time
- About 10 min
- Repair cost
- $200–$500
What the E3 code means
E3 on an LG window or portable air conditioner means the unit has detected that it has no refrigerant, so it cannot cool. LG lists this as a repair-service code, and a leak in the sealed system is the usual cause.
Refrigerant is not used up like fuel. It circulates in a sealed loop, so a unit that has lost its refrigerant almost always has a leak. Adding refrigerant without fixing the leak only works for a short time.
You will usually notice the fan blowing room-temperature air before or alongside E3. On mini-split systems LG uses CH codes instead, so E3 on this page applies to window and portable models.
Common causes
Listed from most to least common.
- Refrigerant leak in the sealed system
- Damage from dropping or tipping the unit during moving or installation
- Sensor or board fault giving a false reading
How to fix the E3 code
Unplug the air conditioner or switch it off at the breaker before removing any panel or filter.
Step 1: Unplug and restart once
Unplug the unit for 2 minutes, plug it back in and run Cool. Feel the air from the vents after 10 minutes.
Step 2: Let it settle if it was moved
If the unit was just carried or laid on its side, leave it upright and off for a few hours before running it again.
Step 3: Look for signs of a leak
With the unit unplugged, look at the copper tubing you can see through the back grille. Oily patches on the tubing or coils often mark where refrigerant escaped.
Step 4: Stop using it if E3 returns
Turn it off. Running a unit with no refrigerant can damage the compressor.
Repair or replace a window AC with E3?
Fixing E3 means finding the leak, brazing it, pulling a vacuum and recharging. On a window or portable unit that often costs close to the price of a new one, so check your warranty and the age of the unit before booking a repair.
If the unit is under warranty, contact LG with the model and serial number from the label on the side. If not, ask a technician for a quote on the leak repair before agreeing to a recharge.
How to reset the LG air conditioner
- Turn the air conditioner off with the remote or the control panel.
- Cut the power for 5 minutes. Unplug window and portable units. For a mini-split, turn off the breaker and the outdoor disconnect switch if there is one.
- Restore power and turn the unit back on. The compressor normally waits about 3 minutes before starting, so give it time before judging.
- If the same code comes back straight away, the fault is still there. Work through the fix steps above, or call a technician.
When to call a technician
E3 needs a repair service to find the leak and recharge the unit. Never try to add refrigerant yourself.
A typical repair for this code costs $200–$500 in the US, including parts and labor. Prices vary by area and model.
Models this applies to
- Ductless mini-splits (wall-mounted and Art Cool)
- Multi-zone mini-split systems
- Window air conditioners
- Portable air conditioners
Codes can differ slightly between models. Your owner's manual is the final word and is available from LG support.
Frequently asked questions
›Should I repair or replace a window AC with E3?
Sealed-system repairs often cost close to the price of a new window unit. Check your warranty first, as some warranties cover the sealed system for longer than other parts.
›Why is my LG window AC blowing warm air with E3?
Without refrigerant, the unit cannot remove heat from the room, so only the fan runs.
›Can I recharge an LG window AC myself?
No. In the US, handling refrigerant requires EPA certification, and the leak has to be found and sealed before a recharge will last.
›Does E3 mean the compressor is broken?
Not necessarily. E3 points to missing refrigerant, not a failed compressor. Running the unit for long with E3 can damage the compressor, though, so switch it off.