Frigidaire refrigerator SH code: shorted temperature sensor
- Urgency
- Medium
- Who can fix it
- Moderate DIY
- Time
- About 15 min
- Repair cost
- $150–$300
A temperature sensor (thermistor) is shorted, so the control gets a false reading. SH in the freezer display points to the freezer sensor, and SH in the fresh food display points to the fresh food sensor. A failed sensor or pinched wire is the usual cause.
Likely causes
Listed from most to least common.
- Failed thermistor
- Pinched sensor wire shorting to the cabinet
- Water or ice in the sensor connector
- Faulty main control board
How to fix the SH code
Unplug the refrigerator or switch it off at the breaker before removing any panel or filter.
Step 1: Note which display shows SH
Write down whether SH is in the freezer (FZ) or fresh food (FF) display.
Step 2: Reset the refrigerator
Unplug it or switch off the breaker for 5 minutes, then restore power.
Step 3: Monitor temperatures
Use an appliance thermometer in each section and move food if the refrigerator rises above 40°F.
You'll need: Appliance thermometer.
Parts that may need replacing
Check your model number on the label inside the door or on the back before ordering.
- Frigidaire refrigerator thermistorCheck prices
When to call a technician
If SH returns after a reset, have a technician test the sensor and its wiring before replacing the control board.
A typical repair for this code costs $150–$300 in the US, including parts and labor. Prices vary by area and model.
Models this applies to
- Gallery and Professional French door refrigerators
- Side-by-side refrigerators
- Bottom-freezer refrigerators
Codes can differ slightly between models. Your owner's manual is the final word and is available from Frigidaire support.
Common questions
›What is the difference between OP and SH?
OP means the sensor circuit is open, like a cut wire. SH means it is shorted. Both stop the control from reading the temperature.
›Can I replace the sensor myself?
Some fresh food sensors clip in behind a cover, but most need panels removed and a meter test. Most owners leave it to a technician.